How to Choose LED Parking Lot Lights: The Ultimate Guide

(Last Updated On: )

Parking lot lighting plays a pivotal role in our daily lives, often taken for granted but never truly appreciated until it’s lacking. As a beacon in the urban landscape, these lights guide us through the darkness, ensuring our safety and convenience during the most mundane tasks – parking our vehicles.

Table of Contents

Chapter 1: Understanding Parking Lot Lighting Needs

Parking lot lighting is not a one-size-fits-all solution; it demands careful consideration of several critical factors to ensure optimal functionality and safety.

A. Illuminance Requirements

1. Light Levels: Determining the correct illuminance levels is paramount. This involves assessing the specific needs of your parking lot, which can vary based on factors such as location, purpose, and surrounding ambient lighting. For instance, commercial parking lots may require higher illuminance levels than residential ones.

2. Illuminance Standards: Familiarize yourself with industry standards and guidelines, often providing recommended minimum illuminance levels for different parking lots. These standards are essential references for ensuring compliance and safety.

3. Zoning Regulations: Be aware of local zoning regulations that may dictate specific lighting requirements for your area. Non-compliance with these regulations can lead to monetary penalties and legal entanglements.

B. Uniformity and Distribution

1. Uniformity: Achieving uniform illumination across the entire parking lot is crucial. Uneven lighting can create dark spots that compromise safety and security. Utilizing photometric analysis and advanced lighting design software can help ensure uniformity.

2. Distribution Patterns: Consider the appropriate light distribution pattern for your parking lot. Wide or narrow distribution patterns should align with the layout and dimensions of the lot. Proper distribution ensures efficient coverage and minimizes light spillage.

C. Light Poles and Mounting Heights

1. Mounting Heights: The height at which you install light poles significantly impacts lighting effectiveness. It’s essential to balance achieving adequate ground coverage and preventing light pollution. Factors like pole spacing and fixture selection influence mounting height decisions.

2. Pole Placement: Position light poles strategically to avoid shadows, especially in corners and walkways. This promotes even lighting and enhances safety for pedestrians and drivers alike.

3. Adherence to Codes: Consult local building codes and regulations concerning pole height and placement. Compliance ensures your lighting system meets safety and legal requirements.

D. Safety and Security Considerations

1. Color Temperature: The perception of safety can be influenced by the unique color temperature of your LED lights. Warmer color temperatures (lower Kelvin values) tend to create a cozier, less harsh environment, while more excellent colors may enhance security but might feel less inviting.

2. Motion Sensors: Incorporating motion sensors into your lighting system can enhance security while conserving energy. Lights can automatically increase brightness when motion is detected, deterring potential threats.

3. Glare Control: Excessive glare from parking lot lights can hinder visibility and create safety hazards. Utilize fixtures and optics designed to reduce glare, ensuring that light is directed where needed without causing discomfort to users.

led lighting in parking structures

Chapter 2: LED Lighting Technology

Understanding the technology behind LED lighting is pivotal in making informed choices for your parking lot.

A. How LEDs Work

1. Semiconductor Magic: LED, or Light Emitting Diode, operates on a fascinating principle. The passage of an electrical current through a semiconductor material induces the emission of photons, generating visible light. This mechanism starkly contrasts traditional incandescent bulbs, which rely on heating a filament to create light and thus waste significant energy as heat.

2. Efficiency in Action: LEDs are exceptionally efficient in converting electrical energy into visible light. Their efficiency reduces energy consumption and minimizes heat generation, making them cool to the touch and safe for prolonged use.

B. Types of LED Lights

1. Retrofit vs. New Installations: Understanding whether you are retrofitting existing fixtures or conducting a new installation is crucial. Retrofitting involves replacing the internal components of existing fixtures with LED technology, which can be cost-effective. On the other hand, new installations offer greater flexibility in fixture selection and design but may require a higher upfront investment.

2. Fixture Selection: LED fixtures come in various shapes and sizes, each tailored to specific lighting needs. Choices range from shoebox lights for large area coverage to wall-mounted fixtures for architectural aesthetics. Fixture selection should align with your parking lot’s layout and illumination requirements.

C. Color Temperature and CRI

1. Color Temperature: The Kelvin (K) measurement is employed to gauge the color temperature of LED lights, which dictates the light’s perceived degree of warmth or coolness. Lower Kelvin values (e.g., 2700K) emit warm, yellowish light, while higher values (e.g., 5000K) produce cooler, bluish light. Parking lots often benefit from cooler temperatures for enhanced visibility, but striking the right balance is essential to maintaining safety and comfort.

2. Color Rendering Index (CRI): CRI measures how accurately LED lights reproduce the true colors of objects. A higher CRI value indicates better color rendering. A CRI above 80 in parking lots is recommended to ensure drivers can distinguish colors accurately, which can be crucial for identifying vehicles and hazards.

D. Light Distribution and Beam Angle

1. Light Distribution: The distribution of light is a critical consideration. LED fixtures have different distribution patterns, such as Type I, II, III, and IV. Your choice of distribution pattern should be guided by your parking lot’s layout and particular requirements, ensuring that you achieve consistent and even illumination.

2. Beam Angle: An LED fixture’s beam angle determines the light’s spread. Narrow beam angles focus light in a specific direction, ideal for pathways or highlighting specific areas. Wider beam angles provide more extensive coverage, suitable for open parking lots. Careful consideration of beam angles ensures that light is directed where needed most.

parking lot lighting fixture

Chapter 3: Benefits of LED Lighting in Parking Sstructures

LED lighting has revolutionized the illumination of parking structures, offering many advantages beyond traditional lighting technologies.

A. Energy Efficiency and Cost Savings

LED lighting stands as a paragon of energy efficiency, redefining how parking structures are illuminated:

1. Cost Reduction: LED lights consume significantly less energy than their incandescent and fluorescent counterparts. This translates into substantial cost savings on electricity bills, a particularly compelling benefit for owners of large parking facilities.

2. Long-Term Savings: The energy efficiency of LED lights extends to their lifespan. These fixtures often last tens of thousands of hours, reducing the frequency of replacements and lowering maintenance costs over time.

3. Reduced Heat Generation: Unlike incandescent bulbs that waste considerable energy as heat, LEDs remain cool to the touch. This conserves energy and enhances safety by minimizing the risk of burns.

B. Longevity and Reduced Maintenance

LED lights are celebrated for their remarkable longevity and minimal maintenance needs:

1. Extended Lifespan: LED fixtures have an impressively long operational life spanning over a decade. This longevity results in fewer replacements and less disruption for maintenance personnel.

2. Durability: LEDs are solid-state lights, meaning they are more resistant to shock, vibration, and extreme temperature fluctuations. Their robust nature ensures reliability even in challenging conditions.

3. Lower Maintenance Costs: With fewer replacements and reduced downtime for maintenance, the total cost of ownership (TCO) of LED lighting is significantly lower than traditional lighting options.

C. Improved Visibility and Safety

In parking structures, visibility and safety are paramount considerations, and LED lighting excels in this regard:

1. Enhanced Visibility: LED lights offer superior light quality with high color rendering, ensuring that colors appear true to life. This heightened visibility is invaluable for drivers and pedestrians, reducing the risk of accidents and improving overall safety.

2. Reduced Shadows and Glare: Well-designed LED lighting systems minimize shadows and glare, creating an even and comfortable illumination. This eliminates dark spots and enhances the sense of security within the parking facility.

3. Dissuading Criminal Activity: Bright LED lighting is a deterrent to criminal activities in parking structures. Well-lit areas are less inviting to wrongdoers, contributing to a safer user environment.

D. Environmental Sustainability

The eco-conscious advantages of LED lighting align with modern sustainability goals:

1. Lower Carbon Footprint: LED lights produce fewer greenhouse gas emissions due to reduced energy consumption. This contributes to a smaller carbon footprint, supporting environmental sustainability efforts.

2. Mercury-Free: Unlike fluorescent lamps, LED lights contain no hazardous materials like mercury. This eliminates the need for special disposal procedures and reduces the risk of environmental contamination.

E. Customization and Control

LED lighting technology offers a high degree of customization and control:

1. Color Temperature: LED lights can be customized to provide various color temperatures, allowing for lighting that aligns with the desired ambiance and functionality of the parking structure.

2. Dimming and Smart Controls: Implementing dimming and intelligent lighting controls enables automatic adjustments of light levels based on occupancy and ambient conditions. This not only enhances energy efficiency but also provides tailored lighting solutions.

3. Len’s Angle: A wide array of lens angle options is accessible across the lighting industry. These lens angles, often called beam angles, determine how light is distributed from a light source. 

A: Wide Beam Angle:

  • A wide beam angle, typically 90 to 120 degrees or more, is designed to disperse light over a broad area.
  • Applications: These lenses are commonly used for general area lighting, floodlights, and fixtures to illuminate large spaces such as outdoor parking lots, open plazas, or sports fields.

B: Medium Beam Angle:

  • Medium beam angles usually fall within the range of 30 to 60 degrees.
  • Applications: They are ideal for accent lighting, spotlighting, and providing focused illumination on specific objects or areas, like artwork in galleries or products in retail displays.

C: Narrow Beam Angle:

  • Narrow beam angles, typically under 30 degrees, concentrate light into a tight, focused beam.
  • Applications: These lenses are well-suited for tasks that demand precision and control, such as highlighting architectural details, accentuating landscaping features, or creating dramatic lighting effects on stages.

D: Spot Beam Angle:

  • Spot beam angles are the narrowest, often below 15 degrees, and produce an intense, highly focused light beam.
  • Applications: Spotlights with spot beam angles are frequently used for long-distance illumination, like highlighting signage or projecting light across a large expanse.

E: Adjustable or Zoom Lenses:

  • Some lighting fixtures feature adjustable or zoom lenses, allowing users to change the beam angle as needed.
  • Applications: These versatile fixtures are employed in scenarios where the lighting requirements may vary, enabling adaptability without changing the fixture.

F: Asymmetric Beam Angle:

  • Asymmetric lenses are designed to direct light in a specific direction, often used for wall washing or illuminating pathways or signage.
  • Applications: These lenses are beneficial for creating uniform, wall-mounted lighting or emphasizing linear features like walkways.

G: Elliptical Beam Angle:

  • Elliptical lenses produce a beam that is wider in one direction and narrower in the other, providing tailored lighting for unique spaces.
  • Applications: Elliptical beam angles are employed when you must evenly illuminate areas with non-standard shapes or dimensions, such as corridors or long, narrow aisles.

H: Frosted or Diffused Lenses:

  • Frosted or diffused lenses scatter light, reducing the harshness of direct illumination and creating a softer, more even light distribution.
  • Applications: These lenses are often used for fixtures intended to provide ambient or decorative lighting, creating a cozy and inviting atmosphere in residential or commercial spaces.

Chapter 4: Types of LED Parking Lot Lights

The evolution of LED technology has ushered in a diverse array of LED parking lot lights, each designed to fulfill specific lighting requirements. In this comprehensive examination, we explore the various types of LED parking lot lights and the considerations associated with their deployment.

A. Area Lights vs. Flood Lights

1. Area Lights:

  • Illuminating Wide Spaces: Area lights are engineered to provide uniform illumination over large areas. They are ideal for parking lots, courtyards, and expansive outdoor spaces.
  • Optimized for Even Light Distribution: These fixtures typically have a broader beam angle, ensuring even light distribution across the ground.
  • Applications: Area lights are commonly employed in commercial parking lots, public plazas, and recreational areas where consistent, widespread illumination is essential.

2. Flood Lights:

  • Focused Intensity: Floodlights are designed to cast an intense, concentrated beam of light over a particular area or object.
  • Customizable Beam Angles: They offer flexibility in adjusting beam angles to suit specific lighting needs, making them versatile fixtures.
  • Applications: Floodlights often highlight architectural features and signage or provide additional security in parking structures.

B. Wall-Mounted vs. Pole-Mounted Fixtures

1. Wall-Mounted Fixtures:

  • Space-Saving Solution: Wall-mounted fixtures are affixed to vertical surfaces, saving ground space while providing adequate lighting.
  • Illuminating Perimeter and Walkways: These fixtures light the periphery of parking lots, building facades, and pedestrian walkways.
  • Applications: Wall-mounted fixtures enhance safety, security, and aesthetics around parking structures, entrances, and exits.

2. Pole-Mounted Fixtures:

  • Optimal Height: Pole-mounted fixtures are elevated on poles or light standards, offering greater height and coverage.
  • Wide Area Coverage: They are well-suited for evenly illuminating larger parking areas, walkways, and open spaces.
  • Applications: Pole-mounted fixtures are commonly seen in parking lots, providing comprehensive, well-distributed lighting for vehicles and pedestrians.

C. Color Temperature and CRI

1. Color Temperature:

  • Warm vs. Cool Lighting: LED lights can be tailored to emit warm or cool light, depending on the desired ambiance.
  • Choosing the Right Temperature: Warm lighting (with lower Kelvins) can establish a welcoming and cozy ambiance, whereas cool lighting (with higher Kelvins) boosts visibility and bolsters security.
  • Applications: Parking lot lighting often leans towards cooler color temperatures to ensure clear visibility, but striking the right balance is crucial.

2. Color Rendering Index (CRI):

  • Accurate Color Representation: CRI measures how faithfully LED lights render colors compared to natural light.
  • Higher CRI for Better Color Accuracy: A higher CRI is important in scenarios where color accuracy is vital, such as retail parking areas or environments where vehicle colors must be distinguished accurately.

D. Motion Sensors and Smart Lighting Controls

1. Motion Sensors:

  • Enhanced Energy Efficiency: Motion sensors can be integrated into LED fixtures to detect movement, automatically adjusting light levels in response.
  • Applications: These sensors are valuable for reducing energy consumption by dimming or turning off lights when no motion is detected, making them ideal for parking lots with varying activity levels.

2. Smart Lighting Controls:

  • Intelligent Lighting Management: Smart lighting systems use advanced controls to manage lighting schedules and brightness levels and even adapt to changing weather conditions.
  • Applications: Smart lighting controls are increasingly popular for larger parking facilities, where precise control and energy optimization are paramount.
types of led parking lot lights

Chapter 5: Lighting Design Considerations

Designing effective and efficient LED lighting systems for parking structures involves meticulous planning and attention to detail.

A. Photometric Analysis

1. Precise Planning: Photometric analysis involves a detailed study of light distribution in a given space. This analysis aids in accurately placing and configuring fixtures to achieve desired lighting outcomes.

2. Optimizing Illuminance: By analyzing photometric data, lighting designers can ensure that light is distributed uniformly across the parking structure, minimizing dark spots and over-illuminated areas.

B. Light Trespass and Glare Control

1. Preventing Light Pollution: Light trespass occurs when light spills beyond the intended area, causing unwanted illumination in neighboring spaces or the night sky. Effective design mitigates light trespass, minimizing environmental impact.

2. Glare Reduction: Reducing glare is critical in ensuring drivers’ and pedestrians’ comfort and safety. Proper fixture selection, shielding, and control are essential for reducing glare.

C. Dark Sky Compliance

Preserving the Night Sky: The objective of dark sky compliance is to mitigate light pollution and safeguard the innate splendor of the nighttime environment. Shielding fixtures and directing light downwards helps achieve dark, sky-friendly designs.

D. Illuminance Levels

Determining Optimal Levels: Proper illuminance levels must be established based on the specific function and use of the parking structure. For instance, higher illuminance may be required at entrances and exits for safety.

E. Uniformity

Balanced Lighting: Achieving uniformity in lighting distribution ensures that every part of the parking structure is adequately lit, eliminating shadowy areas and enhancing safety and aesthetics.

F. Color Rendering

True Color Reproduction: The color rendering index (CRI) is a crucial consideration, especially in parking structures where accurate color identification is necessary, such as distinguishing vehicle colors or reading signage.

G. Lighting Controls and Automation

Intelligent Systems: Incorporating lighting controls and automation enables adaptive lighting solutions. Sensors can adjust lighting levels based on occupancy or daylight conditions, improving energy efficiency and optimizing the user experience.

H. Maximizing Energy Efficiency

1. LED Technology: Leveraging the energy-efficient nature of LED lighting is paramount. Selecting fixtures with the correct wattage, optics, and controls ensures energy is used judiciously without sacrificing illumination quality.

2. Scheduling and Dimming: Timers, scheduling systems, and dimming controls can be employed to reduce energy consumption during off-peak hours or when full brightness is unnecessary.

3. Daylight Harvesting: Implementing daylight harvesting systems that dim or turn off lights in response to natural daylight levels can result in substantial energy savings.

led parking lot lights design

Chapter 6: Choosing the Right LED Parking Lot Lights

Selecting the optimal LED parking lot lights is pivotal in ensuring your lighting system’s functionality, efficiency, and sustainability.

A. Assessing Your Parking Lot’s Needs

  1. Site Evaluation: A thorough evaluation of your parking lot is the foundation of the decision-making process. Consider elements like the dimensions, arrangement, and function of the parking area and the existing environmental conditions.
  2. Illuminance Requirements: Determine the required illuminance levels based on industry standards and the specific use of the parking area. Different areas may require different levels of lighting for optimal safety and functionality.
  3. Uniformity and Distribution: Assess the uniformity of your current lighting and identify areas with inadequate coverage or excessive glare. This evaluation informs your fixture placement and beam angle decisions.

B. Fixture Selection Criteria

  • Type of Fixture: Choose the type of LED that aligns with your parking lot’s requirements, whether it’s area lights, floodlights, wall-mounted fixtures, or a combination.
  • Wattage and Lumen Output: Consider each fixture’s appropriate wattage and lumen output to achieve the desired illuminance levels while optimizing energy efficiency.
  • Color Temperature and CRI: Select the color temperature that balances aesthetics and visibility. High Color Rendering Index (CRI) fixtures may be necessary for areas where accurate color recognition is crucial.
  • Light Distribution: Opt for fixtures with the right beam angle and light distribution pattern to ensure even illumination and minimize light spillage.
  • Durability and Weather Resistance: Given the outdoor environment, prioritize fixtures with high durability and weather-resistant features to withstand varying weather conditions.
  • Energy Efficiency: Evaluate the fixture’s efficiency and compatibility with energy-saving features like dimming controls and motion sensors.

C. Considerations for Retrofitting

  1. Compatibility: When retrofitting existing fixtures with LED technology, ensure compatibility between the LED retrofit kits and the existing infrastructure.
  2. Cost Analysis: Perform a comprehensive cost-benefit assessment to ascertain the potential long-term savings and return on investment (ROI) when retrofitting is compared to the option of new installations.
  3. Regulatory Compliance: Verify that retrofitting complies with local building codes and energy regulations, as non-compliance can lead to legal complications.

D. Vendor and Product Research

  1. Vendor Reputation: Research and evaluate the reputation of LED lighting vendors. Take into account elements like the quality of the product, the level of customer service provided, and the overall reliability of the offerings.
  2. Product Specifications: Review product specifications, including warranties, to ensure they meet your requirements and provide long-term reliability.
  3. Customer Reviews and Testimonials: Seek feedback from previous customers and read testimonials to gain insights into the performance and durability of specific products.
  4. Energy Efficiency Certifications: Look for ENERGY STAR-certified fixtures compliant with other energy efficiency standards, which can help you identify energy-efficient options.
  5. Samples and Trials: Request samples or conduct trials to test the performance of LED fixtures in your parking lot environment before making a final decision.
parking lot lighting fixture layout

Chapter 7: Installation and Maintenance Best Practices

Installing and maintaining LED parking lot lights are critical to ensuring the long-term performance, energy efficiency, and safety of your lighting system.

A. Proper Installation Guidelines

  1. Compliance with Regulations: Ensure the installation adheres to local building codes, zoning regulations, and safety standards. Non-compliance can lead to legal complications and safety hazards.
  2. Professional Installation: Enlist the services of experienced and qualified professionals for the installation. Proper installation not only ensures the safety of the lighting system but also maximizes its efficiency and lifespan.
  3. Fixture Placement: Position fixtures strategically to achieve uniform illumination across the parking lot. Avoid shadows, dark spots, and over-illuminated areas by carefully considering the layout and spacing of fixtures.
  4. Electrical Connections: Ensure secure electrical connections to prevent loose wiring or potential hazards. Proper grounding is essential for electrical safety.
  5. Optics and Angles: Verify that fixtures are correctly oriented with the intended beam angles to minimize light spillage and glare. Precise aiming ensures that light is directed where it’s needed most.

B. Routine Maintenance Procedures

  • Scheduled Inspections: Establish a regular inspection schedule to identify issues promptly. Inspections should cover fixtures, wiring, and controls. Consider monthly, quarterly, or semi-annual inspections depending on usage and environmental conditions.
  • Cleaning: Clean fixtures and lenses from dust, dirt, and debris. Accumulated dirt can reduce light output and impact efficiency.
  • Lamp Replacement: LEDs have a long lifespan, but occasional lamp replacement may be necessary. Follow manufacturer recommendations for replacement intervals.
  • Control Systems: Ensure lighting control systems, including timers and motion sensors, function correctly. Calibrate and adjust settings as needed to optimize energy savings.
  • Electrical Safety: Periodically inspect electrical connections and conduits for signs of wear, corrosion, or damage. Address any issues promptly to prevent electrical hazards.
  • Environmental Considerations: Assess the impact of environmental factors, such as weather and temperature fluctuations, on fixtures and wiring. Take preventive measures as needed.

C. Troubleshooting and Repairs

  1. Documentation: Maintain detailed installation records, including fixture specifications and wiring diagrams. These records can be invaluable for troubleshooting and repairs.
  2. Diagnostic Tools: Furnish maintenance personnel with indispensable diagnostic tools and equipment for efficient problem identification and resolution.
  3. Timely Repairs: Address any malfunctions or damages promptly. Timely repairs prevent further deterioration and potential safety hazards.
  4. Qualified Technicians: Utilize trained and qualified technicians for troubleshooting and repairs. Avoid DIY repairs, which can lead to further complications and safety risks.
  5. Warranty Coverage: Familiarize yourself with the warranty coverage for your LED fixtures. Some issues may be covered by warranties, reducing repair costs.

Chapter 8: Future Trends in LED Parking Lot Lighting

In the ever-evolving world of LED parking lot lighting, staying ahead is essential to harness the latest technological advancements, sustainability, and functionality.

A. Emerging Technologies

  1. Li-Fi Integration: Light Fidelity (Li-Fi) technology is emerging as a potential game-changer in parking lot lighting. It uses visible light communication to transmit data, offering high-speed wireless internet access. In the future, LED fixtures may double as Li-Fi transmitters, providing illumination and connectivity.
  2. Advanced Sensors: Integrating sophisticated sensors, such as radar and LiDAR, within LED fixtures will enable enhanced detection and response capabilities. These sensors will not only improve security but also facilitate intelligent parking management.
  3. Energy Harvesting: Future LED fixtures may incorporate energy harvesting technologies like piezoelectric and photovoltaic systems. These systems can capture and store energy from various sources, improving energy efficiency.

B. Smart Parking Lot Lighting Solutions

  • IoT Integration: The Internet of Things (IoT) will play a pivotal role in intelligent parking lot lighting. LED fixtures will have sensors and connectivity to communicate with central control systems. This enables real-time monitoring, data analysis, and adaptive lighting adjustments.
  • Predictive Maintenance: Smart lighting systems will employ predictive algorithms to anticipate and schedule maintenance based on fixture performance data. Taking a proactive approach like this helps minimize periods of inactivity and lowers the expenses associated with care.
  • Adaptive Lighting: LED fixtures will dynamically adjust brightness levels and distribution patterns based on occupancy, traffic flow, and environmental conditions. This not only optimizes energy use but also enhances safety and user experience.
  • Integration with Parking Management: Parking lot lighting will be closely integrated with parking management systems. Sensors will detect available parking spaces, directing drivers to open spots and reducing congestion.

C. Sustainability and Environmental Initiatives

  1. Solar-Powered LED Lighting: Integrating solar panels into LED fixtures will become more common, reducing reliance on the grid and further enhancing the sustainability of parking lot lighting.
  2. Biodiversity-Friendly Lighting: Lighting designs will consider the impact on local flora and fauna. Implementations like warm-colored LED lighting with minimal pollution will help preserve natural ecosystems.
  3. Circular Economy: Manufacturers will increasingly adopt a circular economy approach, designing fixtures for easy disassembly and recycling. This reduces waste and promotes sustainability.
  4. Carbon Neutrality: Many organizations are committing to achieving carbon neutrality. LED lighting manufacturers and users will strive to reduce carbon emissions through energy-efficient fixtures and renewable energy sources.
  5. Regulatory Compliance: Expect stricter regulations related to energy efficiency and environmental impact. Compliance with these regulations will drive innovation in sustainable LED parking lot lighting solutions.

Conclusion

With this knowledge, you can decide about your parking lot lighting. As technology evolves, the future of LED parking lot lighting promises more innovative, more sustainable solutions that enhance safety and environmental responsibility. Stay informed, engage with professionals, and continue to explore innovative lighting solutions as you light the path forward for your parking lot’s illumination needs.

Why Choose LED Parking Lot Lights from Upward Lighting

Opting for LED parking lot lights from Upward Lighting is a prudent choice. With over a decade of experience in the LED industry, Upward Lighting offers high-quality, competitively priced fixtures backed by excellent after-sale service. Their commitment to customer satisfaction, compliance with safety regulations, and dedication to energy efficiency make them a reliable and trusted provider.

Upward Lighting’s diverse product range, innovative solutions, and focus on sustainability further solidify its position as a top choice for LED parking lot lighting needs.

Request A Quote for Your Lighting Projects!

Share This Post Now:

Hey there, I'm Michael

I’m from Upward Lighting. We are a professional Outdoor led lighting manufacture in China since 2009. We provide high quality led lighting products for indoor and outdoor projects.

Find Some Other Interesting Topics

Request a Free Quote

We will be back to you within 6 Hours

china led outdoor lighting

Landscape
And Facade

Lighting Fixtures

Architectural Floodlight | Led Wall Washer | Inground Light | Led Pool Light | Led Street Light | Palm Tree Light | Led Garden Light | Outdoor Wall Light | Led Stadium Light | Led Fountain Light | Led Highbay Light | Led Underwater Light

Download Our Full Catalog

Get notified about new products

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.